Phantom Turbo Manifold Gearbox Hayward AX6000MA3GA
January 24, 2013 in Hayward Phantom-Viper by PoolSpaRemote
Hayward Phantom Turbo Manifold Gearbox AX6000MA3GA AX6000MA3GA & AX6000MA3GABK Turbo Manifold Gearbox kit removal Installation Instructions. Turn cleaner over so suction inlet is facing upwards and remove 5 screws (N1) Turn cleaner back over to sit on its wheels and carefully remove deck assembly (N2) Remove 2 floats (N3) and vactube (N4) Remove manifold retaining screw (N5) and lift out manifold / gearbox assy (N6) taking care to disengage gearbox linkage (N7) from switch assy (N8) in lower housing. Lift out lower spinout jet (N9) from its location with lower housing. Remove tank assy (N10)from old manifold by removing 2 screws (N11) Install tank assy (N10) on new manifold and replace 2 screws (N11). Install new manifol Gearbox assy (N6) making sure gearbox switch linkage (N7) engages with switch assembly (N8) Replace front spinout jet (N9) on lower housin and replace manifold retaining screw (N5) Replace 2 floats (N3) and vactube (N4) Replace deck assembly (N2) , carefully turn cleaner over so suction inlet faces upwards. Replace 5 deck mounting screws (N1) Maintenance Update Phantom/Viper Turbo Manifold Inlet Filter Screen. Inlet Filter Screen is available as spare part AX6004R1. Inlet filter screen stays in manifold inlet when hose is removed