.Eagle Pump Diagram
January 24, 2013 in American Eagle Pump by PoolSpaRemote
.American Eagle Pump Diagram
TROUBLESHOOTING
Failure to Pump
- Pump will not prime – too much air.
Check suction piping and valve glands on any
suction gate valves. Secure lid on pump strainer
pot and make sure lid gasket is in place. Check
water level to make sure skimmer is not drawing air. - Pump will not prime – too little water.
Make sure suction lines, pump strainer, and pump
volute are full of water. Make sure valve on
suction line is working and open (some systems
do not have valves). Check water level to make
sure water is available through skimmer. - Pump strainer clogged.
Clean pump strainer pot. - Pump strainer gasket defective.
Replace gasket.
Reduced Capacity and/or Head
- Air pockets or leaks in suction line.
Check suction piping and valve glands on any
suction gate valves. Secure lid on pump strainer
pot and make sure lid gasket is in place. Check
water level to make sure skimmer is not drawing air. - Clogged impeller.
Remove, clean and adjust. - Pump strainer clogged.
Clean suction trap.
1 | 39200200 | Lid, clear | |
2 | 39204100 | O-ring | |
3 | 39200100 | Basket | |
4 | 39201700 | Integral pot & volute, 2″ suction port | |
4a | 39201100 | Volute, booster | |
5 | 98206400 | Plug, 1/4″ with O-ring | |
6 | 39200300 | O-ring, volute | |
7 | 39204600 | Reinforcing ring, S/S | |
8 | 39204800 | Gasket | |
9 | 39204700 | Diffuser | |
10 | 39200600 | Impeller, 3/4 HP | |
39200700 | Impeller, 1 HP | ||
39200800 | Impeller, 1-1/2 HP | ||
39200900 | Impeller, 2 HP | ||
11 | 39702000 | Seal 1000 | |
12 | 39201000 | Seal Plate | |
13 | 98203400 | Bolt, hex, 3/8 – 16 x 3/4″ | |
14 | 98210300 | Washer, Flat, 3/8″ | |
15 | 98216200 | Bolt, hex, 3/8 – 16 x 1-1/4″ | |
16 | 37413000 | Nut | |
17 | 39201300 | Support, motor | |
18 | 98203000 | Screw 13-16 x 3/4″ high-low | |
19 | 37413000 | Nut, hex 3/8-16, volute to seal plate |