Hayward Ignitor Silicon Nitride IDXL2IGN1930

January 24, 2013 in Hayward Heaters Parts by PoolSpaRemote

Hayward Heater Silicon Nitride Ignitor IDXL2IGN1930 Used on the following models: H250IDL2, H350IDL2 & H400IDL2 To replace Hot Surface Ignitor: Turn pump, main gas valve, and heater power off. Remove front access door. Disconnect igniter leads plug from wire harness plug. Remove two screws that fasten ignitor. Replace defective ignitor and reverse the above procedure.

Hayward Heater HI-Limit 135F HAXHLI1930

January 24, 2013 in Hayward Heaters Parts by PoolSpaRemote

Hayward H-Series Low NOx, ED2 Heater HI-Limit 135F HAXHLI1930

Hayward Ignition Module PROP CHXMOD1932

January 24, 2013 in Hayward Heaters Parts by PoolSpaRemote

Hayward Heater Ignition Module PROP CHXMOD1932 IGNITION MODULE -PROP. CZ, HM2, CPS, SG Input- 24 VAC, 50/60Hzm, Spark Gap 7/64IN TH current =0.250 AMP +PV + MV At 24 VAC PV or MV Load Max = 1.5 AMP at 0.5PF

Transformer Hayward 120-240V-24VAC IDXL2TRF1930

January 24, 2013 in Hayward Heaters Parts by PoolSpaRemote

Hayward 120/240V-24VAC Transformer IDXL2TRF1930

Hayward Wire Harness IDXLWHM1930

January 24, 2013 in Hayward Heaters Parts by PoolSpaRemote

Hayward H-Series Low NOx Heater Wire Harness IDXLWHM1930

Thermostat Hayward H-Series Heater IDXTST1930

January 24, 2013 in Hayward Heaters Parts by PoolSpaRemote

Thermostat for Hayward H-Series Heater IDXTST1930

Hayward Water Pressure Switch HAXPSA1930

January 24, 2013 in Hayward Heaters Parts by PoolSpaRemote

Hayward Pressure Switch HAXPSA1930 Used on Hayward H-Series From 250.000 BTU To 400.000 BTU

Hayward Bezel Keypad FD FDXLBKP1930

January 24, 2013 in Hayward Heaters Parts by PoolSpaRemote

Hayward FD Heater Bezel Keypad FDXLBKP1930

Hayward Heater Thermistor IDXLTER1930

January 24, 2013 in Hayward Heaters Parts by PoolSpaRemote

Hayward H-Series Low NOx Heater Thermistor IDXLTER1930

Pressure Switch Hayward FD Heater FDXLWPS1930

January 24, 2013 in Hayward Heaters Parts by PoolSpaRemote

Hayward FD Heater Pressure Switch FDXLWPS1930 Water Pressure Switch Replacement Procedure. FDXLWPS1930 for Universal H-Series (Forced-Draft) Heaters IMPORTANT NOTES: This kit is intended to be used only with Hayward Universal H-Series (forced-draft) gas heater models. These heaters may be identified by inspection of the heater rating plate (there should be an “FD” in the model number), or by visual inspection of the heater in comparison to the diagrams in these instructions. REPLACEMENT PROCEDURE Turn pump, main gas valve, and heater power off. Remove 6 screws and remove the upper plastic heater side panel, to allow access to the header (see Figure 1 for screw locations). Disconnect wires from pressure switch. Remove pressure switch by un-threading it from the header (see Figure 2 for pressure switch location). Install new pressure switch in header. Apply pipe thread sealant to pressure switch threads before assembly. Use care to not cross-thred the pressure switch when threading into the header. Connect wires to new pressure switch. Test operation of the pressure switch and adjust if necessary (see below). Re-install upper plastic heater side panel. TEST / ADJUSTMENT PROCEDURE The pressure switch is preset at the factory for most typical, deck level installations. When the heater